Optimized Control of a Novel DC/3AC Converter Topology with Reduced Component Effort

  • Author:

    Christian Axtmann, Johannes Kolb, Michael Braun

  • Source:

    2018 20th European Conference on Power Electronics and Applications (EPE'18 ECCE Europe)

  • Date: 17.09.-21-09.2018 Riga, Lettland
  • A previously proposed converter topology can reduce component effort and converter volume by decreasing the pulsed voltage across the DC-converter inductance. However, the machines maximum phase voltage then becomes a function of the DC source voltage. In this paper, an optimization is presented to ensure a constant maximum phase voltage over a wide source voltage spread.